Specificatii
Marca
BlockProduct Type
PCB Transformer
Secondary Voltage
15 V
Primary Voltage
230 V
Numar iesiri
2
Lungime
32.8mm
Latime
32.8mm
Adancime
27.8mm
Power
1.5VA
Greutate
80g
Montare
Through Hole
PCB Transformer Current
0.05A
Temperatura minima de lucru
-20°C
Temperatura maxima de lucru
85°C
Series
VB EI 30/12.5
Minimum Operating Frequency
50Hz
Maximum Operating Frequency
60Hz
Standards/Approvals
CE, VDE, cURus, UL 51, EN 615586 009, RoHS, CSA . E1051
Tara de origine
China
Detalii Produs
The Block PCB transformer production processes undergo adjustments to both visual appearance and technical characteristics. Slight variations in no-load voltages and efficiency may occur, though the pinning remains identical to the previous version. These transformers ensure galvanic isolation between primary and secondary circuits, featuring a special construction for absolute short-circuit safety. Additionally, they meet all requirements for supplying Safety Extra Low Voltage (SELV) circuits.
Informatii despre stoc temporar indisponibile
€ 11,40
€ 11,40 Buc. (fara TVA)
€ 13,79
€ 13,79 Buc. (cu TVA)
1
€ 11,40
€ 11,40 Buc. (fara TVA)
€ 13,79
€ 13,79 Buc. (cu TVA)
Informatii despre stoc temporar indisponibile
1
| Cantitate | Pret unitar |
|---|---|
| 1 - 9 | € 11,40 |
| 10 - 49 | € 9,21 |
| 50 - 99 | € 7,18 |
| 100+ | € 6,40 |
Documente Tehnice (Imaginile sunt cu titlu informativ. Va rugam sa consultati specificatiile tehnice.)
Specificatii
Marca
BlockProduct Type
PCB Transformer
Secondary Voltage
15 V
Primary Voltage
230 V
Numar iesiri
2
Lungime
32.8mm
Latime
32.8mm
Adancime
27.8mm
Power
1.5VA
Greutate
80g
Montare
Through Hole
PCB Transformer Current
0.05A
Temperatura minima de lucru
-20°C
Temperatura maxima de lucru
85°C
Series
VB EI 30/12.5
Minimum Operating Frequency
50Hz
Maximum Operating Frequency
60Hz
Standards/Approvals
CE, VDE, cURus, UL 51, EN 615586 009, RoHS, CSA . E1051
Tara de origine
China
Detalii Produs
The Block PCB transformer production processes undergo adjustments to both visual appearance and technical characteristics. Slight variations in no-load voltages and efficiency may occur, though the pinning remains identical to the previous version. These transformers ensure galvanic isolation between primary and secondary circuits, featuring a special construction for absolute short-circuit safety. Additionally, they meet all requirements for supplying Safety Extra Low Voltage (SELV) circuits.