Documente Tehnice (Imaginile sunt cu titlu informativ. Va rugam sa consultati specificatiile tehnice.)
Specificatii
Marca
BlockSecondary Voltage
18 V
Product Type
PCB Transformer
Primary Voltage
230 V
Numar iesiri
1
Lungime
23mm
Latime
23mm
Adancime
24mm
Power
0.5VA
Greutate
35g
Montare
Through Hole
PCB Transformer Current
0.028A
Frecventa minima de auto-rezonanta
-20°C
Temperatura maxima de lucru
70°C
Series
VB
Minimum Operating Frequency
50Hz
Standards/Approvals
RoHS, VDE, EN 615586 009, UL 51, cURus, CSA . E1051, CE
Maximum Operating Frequency
60Hz
Tara de origine
China
Detalii Produs
The Block PCB transformer production processes undergo adjustments to both visual appearance and technical characteristics. Slight variations in no-load voltages and efficiency may occur, though the pinning remains identical to the previous version. These transformers ensure galvanic isolation between primary and secondary circuits, featuring a special construction for absolute short-circuit safety. Additionally, they meet all requirements for supplying Safety Extra Low Voltage (SELV) circuits.
Informatii despre stoc temporar indisponibile
€ 11,44
€ 11,44 Buc. (fara TVA)
€ 13,84
€ 13,84 Buc. (cu TVA)
1
€ 11,44
€ 11,44 Buc. (fara TVA)
€ 13,84
€ 13,84 Buc. (cu TVA)
Informatii despre stoc temporar indisponibile
1
| Cantitate | Pret unitar |
|---|---|
| 1 - 9 | € 11,44 |
| 10 - 49 | € 9,27 |
| 50 - 99 | € 7,21 |
| 100+ | € 6,42 |
Documente Tehnice (Imaginile sunt cu titlu informativ. Va rugam sa consultati specificatiile tehnice.)
Specificatii
Marca
BlockSecondary Voltage
18 V
Product Type
PCB Transformer
Primary Voltage
230 V
Numar iesiri
1
Lungime
23mm
Latime
23mm
Adancime
24mm
Power
0.5VA
Greutate
35g
Montare
Through Hole
PCB Transformer Current
0.028A
Frecventa minima de auto-rezonanta
-20°C
Temperatura maxima de lucru
70°C
Series
VB
Minimum Operating Frequency
50Hz
Standards/Approvals
RoHS, VDE, EN 615586 009, UL 51, cURus, CSA . E1051, CE
Maximum Operating Frequency
60Hz
Tara de origine
China
Detalii Produs
The Block PCB transformer production processes undergo adjustments to both visual appearance and technical characteristics. Slight variations in no-load voltages and efficiency may occur, though the pinning remains identical to the previous version. These transformers ensure galvanic isolation between primary and secondary circuits, featuring a special construction for absolute short-circuit safety. Additionally, they meet all requirements for supplying Safety Extra Low Voltage (SELV) circuits.