Documente Tehnice (Imaginile sunt cu titlu informativ. Va rugam sa consultati specificatiile tehnice.)
Specificatii
Marca
RosemountProduct Type
Vibrating Level Switch
Tip dispozitiv
Fork Level Switch
Montare
Side, Top Mount
Housing Material
Stainless Steel
Temperatura minima de lucru
-40°C
Temperatura maxima de lucru
150°C
Maximum AC Voltage
264V ac
Maximum DC Voltage
60V dc
Maximum Current
500mA
Presiune maxima
100bar
Standards/Approvals
EHEDG
Hazardous Area Certification
No
Series
2110
Tara de origine
China
Detalii Produs
The Rosemount Liquid Level Switch is designed using the principle of a tuning fork. A piezo-electric crystal oscillates the forks at their natural frequency. The frequency of the vibrating fork sensor changes depending on the medium in which it is immersed. The denser the liquid, the lower the frequency. When used as a low-level alarm, the liquid in the tank or pipe drains down past the fork, causing a change of natural frequency that is detected by the electronics and switches the output state. When 2110 is used as a high-level alarm, the liquid rises in the tank or pipe, making contact with the fork which then causes the output state to switch.
Informatii despre stoc temporar indisponibile
€ 305,25
€ 305,25 Buc. (fara TVA)
€ 369,35
€ 369,35 Buc. (cu TVA)
1
€ 305,25
€ 305,25 Buc. (fara TVA)
€ 369,35
€ 369,35 Buc. (cu TVA)
Informatii despre stoc temporar indisponibile
1
Documente Tehnice (Imaginile sunt cu titlu informativ. Va rugam sa consultati specificatiile tehnice.)
Specificatii
Marca
RosemountProduct Type
Vibrating Level Switch
Tip dispozitiv
Fork Level Switch
Montare
Side, Top Mount
Housing Material
Stainless Steel
Temperatura minima de lucru
-40°C
Temperatura maxima de lucru
150°C
Maximum AC Voltage
264V ac
Maximum DC Voltage
60V dc
Maximum Current
500mA
Presiune maxima
100bar
Standards/Approvals
EHEDG
Hazardous Area Certification
No
Series
2110
Tara de origine
China
Detalii Produs
The Rosemount Liquid Level Switch is designed using the principle of a tuning fork. A piezo-electric crystal oscillates the forks at their natural frequency. The frequency of the vibrating fork sensor changes depending on the medium in which it is immersed. The denser the liquid, the lower the frequency. When used as a low-level alarm, the liquid in the tank or pipe drains down past the fork, causing a change of natural frequency that is detected by the electronics and switches the output state. When 2110 is used as a high-level alarm, the liquid rises in the tank or pipe, making contact with the fork which then causes the output state to switch.