Documente Tehnice (Imaginile sunt cu titlu informativ. Va rugam sa consultati specificatiile tehnice.)
Specificatii
Marca
BurkertProduct Type
Flow Controller
Tip terminal
Cable Plug
Control Output
PNP
Montare
Compact
Maximum Pipe Diameter
65mm
Frecventa minima de auto-rezonanta
-15°C
Tensiune de alimentare maxima
36V dc
Temperatura maxima de lucru
60°C
Hazardous Area Certification
ATEX
Standards/Approvals
EMC
Curent nominal
100mA
Series
8030
Tara de origine
France
Detalii Produs
The Burkert flow transmitter + sensor has an open collector (PNP/NPN) type output and cable plug electrical connection device. It is designed to measure the continuous flow of liquids. Its operating voltage rating ranges between 12VDC and 36VDC. This sensor produces a signal which can be transmitted and processed enabling the end-user to get a flow measurement. The division is performed by measuring the pulses for the required unit of flow (litres per min.) and then, by the use of four rotary switches on the divider unit (discontinued) - that it is on top of the transmitter to divide signals enabling the output to be tailored to individual requirements. The correct dividing factor can be set up to give the required pulses out for the flow rate.
Informatii despre stoc temporar indisponibile
€ 220,98
€ 220,98 Buc. (fara TVA)
€ 267,39
€ 267,39 Buc. (cu TVA)
1
€ 220,98
€ 220,98 Buc. (fara TVA)
€ 267,39
€ 267,39 Buc. (cu TVA)
Informatii despre stoc temporar indisponibile
1
Documente Tehnice (Imaginile sunt cu titlu informativ. Va rugam sa consultati specificatiile tehnice.)
Specificatii
Marca
BurkertProduct Type
Flow Controller
Tip terminal
Cable Plug
Control Output
PNP
Montare
Compact
Maximum Pipe Diameter
65mm
Frecventa minima de auto-rezonanta
-15°C
Tensiune de alimentare maxima
36V dc
Temperatura maxima de lucru
60°C
Hazardous Area Certification
ATEX
Standards/Approvals
EMC
Curent nominal
100mA
Series
8030
Tara de origine
France
Detalii Produs
The Burkert flow transmitter + sensor has an open collector (PNP/NPN) type output and cable plug electrical connection device. It is designed to measure the continuous flow of liquids. Its operating voltage rating ranges between 12VDC and 36VDC. This sensor produces a signal which can be transmitted and processed enabling the end-user to get a flow measurement. The division is performed by measuring the pulses for the required unit of flow (litres per min.) and then, by the use of four rotary switches on the divider unit (discontinued) - that it is on top of the transmitter to divide signals enabling the output to be tailored to individual requirements. The correct dividing factor can be set up to give the required pulses out for the flow rate.