Honeywell 2CPS Rope Pull Switch 152.4 mm, Dual Direction, 1 NO/1 NC

Nr. stoc RS: 820-3333Producator: HoneywellCod de producator: 2CPSA1A1
brand-logo

Documente tehnice (Imaginile sunt cu titlu informativ. Va rugam sa consultati specificatiile tehnice.)

Specificatii

Product Type

Rope Pull Switch

Configurare contact

1 NO/1 NC

Montare

Dual Direction

Indicator Type

LED

Protectie IP

IP67

Number of Cable Entries

3

Series

2CPS

Contact AC Voltage

250V ac

E-Stop Button

Yes

Reset Button

Yes

Temperatura minima de lucru

-40°C

Contact DC Voltage

60V dc

Contact Current

10A

Temperatura maxima de lucru

80°C

Housing Material

Die Cast Zinc

Lungime

152.4mm

Adancime

92.9mm

Standards/Approvals

UL, CSA, ISO, EN, SIL, CE

Latime

152.4mm

Hazardous Area Certification

No

Mechanical Life

1000000Operations

Conduit Entry

1/2 in NPT

Detalii produs

Honeywell 2CPS Cable Pull Safety Switches

The 2CPS cable pull safety switch range is suitable for covering long distances by allowing the user to run a cable in opposite directions from the unit. Each cable can be up to 76 meters allowing for a combined length of 152 meters. This means they are more cost effective than using a comparable multiple emergency stop push button system.

The internal mechanism is latched by both a push and pull action. This provides extra protection should the cable become slackened or broken over time. A midpoint cable tension window indicates the correct cable tension making it easy to set up. Once the contacts have been switched they must be reset by resetting the cable to the correct tension level and manually rotating the rest knob.

For extra protection a set of auxiliary contacts are switched when the main contact open allowing for monitoring or signalling equipment to be activated such as a flashing beacon. The auxiliary contacts are electrically isolated form the direct acting switch contacts meaning a closed circuit can be maintained even when the main contacts are in the open position.

Compliance
The 2CPS complies with: Low Voltage Directive 73/23/EEC, as amended by directive 93/68/EEC; Machinery Directive 98/37/EEC only as the directives relate to the components being used in a safety function; IEC/EN60947-1; IEC/EN60947-5-1; IEC/EN60947-5-5; UL, CE, CSA, SIL 3 capable.

Informatii despre stoc temporar indisponibile

€ 901,37

€ 901,37 Buc. (fara TVA)

€ 1.090,66

€ 1.090,66 Buc. (cu TVA)

Honeywell 2CPS Rope Pull Switch 152.4 mm, Dual Direction, 1 NO/1 NC

€ 901,37

€ 901,37 Buc. (fara TVA)

€ 1.090,66

€ 1.090,66 Buc. (cu TVA)

Honeywell 2CPS Rope Pull Switch 152.4 mm, Dual Direction, 1 NO/1 NC

Informatii despre stoc temporar indisponibile

Documente tehnice (Imaginile sunt cu titlu informativ. Va rugam sa consultati specificatiile tehnice.)

Specificatii

Product Type

Rope Pull Switch

Configurare contact

1 NO/1 NC

Montare

Dual Direction

Indicator Type

LED

Protectie IP

IP67

Number of Cable Entries

3

Series

2CPS

Contact AC Voltage

250V ac

E-Stop Button

Yes

Reset Button

Yes

Temperatura minima de lucru

-40°C

Contact DC Voltage

60V dc

Contact Current

10A

Temperatura maxima de lucru

80°C

Housing Material

Die Cast Zinc

Lungime

152.4mm

Adancime

92.9mm

Standards/Approvals

UL, CSA, ISO, EN, SIL, CE

Latime

152.4mm

Hazardous Area Certification

No

Mechanical Life

1000000Operations

Conduit Entry

1/2 in NPT

Detalii produs

Honeywell 2CPS Cable Pull Safety Switches

The 2CPS cable pull safety switch range is suitable for covering long distances by allowing the user to run a cable in opposite directions from the unit. Each cable can be up to 76 meters allowing for a combined length of 152 meters. This means they are more cost effective than using a comparable multiple emergency stop push button system.

The internal mechanism is latched by both a push and pull action. This provides extra protection should the cable become slackened or broken over time. A midpoint cable tension window indicates the correct cable tension making it easy to set up. Once the contacts have been switched they must be reset by resetting the cable to the correct tension level and manually rotating the rest knob.

For extra protection a set of auxiliary contacts are switched when the main contact open allowing for monitoring or signalling equipment to be activated such as a flashing beacon. The auxiliary contacts are electrically isolated form the direct acting switch contacts meaning a closed circuit can be maintained even when the main contacts are in the open position.

Compliance
The 2CPS complies with: Low Voltage Directive 73/23/EEC, as amended by directive 93/68/EEC; Machinery Directive 98/37/EEC only as the directives relate to the components being used in a safety function; IEC/EN60947-1; IEC/EN60947-5-1; IEC/EN60947-5-5; UL, CE, CSA, SIL 3 capable.