Documente tehnice
Specificatii
Marca
FlukeMultimeter Type
Handheld
Model
116
Tip afisare
Digital
Model
116
Functie
AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance, Temperature
Absolute Maximum DC Current Measurement
600µA dc
Absolute Maximum Resistance Measurement
40MΩ
Absolute Maximum DC Voltage Measurement
600V dc
Absolute Maximum AC Current Measurement
600µA ac
Absolute Maximum AC Voltage Measurement
600V ac
Absolute Maximum Temperature Measurement
+400°C
Absolute Maximum Capacitance Measurement
9.999F
Frecventa maxima
1kHz
AC Current Measurement Resolution
0.1µA ac
DC Current Measurement Resolution
0.1µA dc
Rezistenta
100mΩ
DC Voltage Measurement Resolution
0.1mV dc
AC Voltage Measurement Resolution
0.1mV ac
Capacitate
1nF
Temperature Measurement Resolution
0.1°C
Safety Category Level
CAT III
Best DC Voltage Accuracy
±0.5% + 2 Digits
Temperatura maxima de lucru
+50°C
Best AC Current Accuracy
±1.5% + 3 Digits
Latime
84mm
Dimensiuni
46 x 84 x 167mm
Best Temperature Measurement Accuracy
±1% + 1 °C
Best AC Voltage Accuracy
±1% + 3 Digits
Best Capacitance Measurement Accuracy
±1.9% + 2 Digits
Temperatura minima de lucru
-10°C
Inaltime
167mm
Greutate
550g
Best DC Current Accuracy
±1% + 2 Digits
Safety Category Voltage
600V
Battery Type
9V
Best Resistance Measurement Accuracy
±1.5% + 2 Digits
Lungime
46mm
Tara de origine
China
Detalii produs
Fluke 16 True RMS HVAC Digital Multimeter with Built-In Thermometer
The Fluke 16 Digital Multimeter is designed to function like a standard Multimeter and exclusive HVAC modes, unlike other models in the Fluke 10 series, the Fluke 116 comes with a built-in thermometer, allowing engineers to measure temperature and microamp mode for testing flame sensors to quickly troubleshoot problems for HVAC applications. The Fluke 116 measures resistance, continuity, frequency and capacitance. The Fluke 116 Multimeter are independently tested for safe use in CAT III 600 V Environments.
Standards
From Fluke, the 116 is designed for heating, ventilation and air conditioning (HVAC) engineers. The model includes temperature measurement and microamp current ranges to quickly troubleshoot HVAC problems.
Informatii indisponibile despre stoc
Incercati din nou mai tarziu
€ 402,50
Buc. (fara TVA)
€ 478,98
Buc. (cu TVA)
Tip calibrare
Fara calibrare
1
€ 402,50
Buc. (fara TVA)
€ 478,98
Buc. (cu TVA)
Tip calibrare
Fara calibrare
1
Documente tehnice
Specificatii
Marca
FlukeMultimeter Type
Handheld
Model
116
Tip afisare
Digital
Model
116
Functie
AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance, Temperature
Absolute Maximum DC Current Measurement
600µA dc
Absolute Maximum Resistance Measurement
40MΩ
Absolute Maximum DC Voltage Measurement
600V dc
Absolute Maximum AC Current Measurement
600µA ac
Absolute Maximum AC Voltage Measurement
600V ac
Absolute Maximum Temperature Measurement
+400°C
Absolute Maximum Capacitance Measurement
9.999F
Frecventa maxima
1kHz
AC Current Measurement Resolution
0.1µA ac
DC Current Measurement Resolution
0.1µA dc
Rezistenta
100mΩ
DC Voltage Measurement Resolution
0.1mV dc
AC Voltage Measurement Resolution
0.1mV ac
Capacitate
1nF
Temperature Measurement Resolution
0.1°C
Safety Category Level
CAT III
Best DC Voltage Accuracy
±0.5% + 2 Digits
Temperatura maxima de lucru
+50°C
Best AC Current Accuracy
±1.5% + 3 Digits
Latime
84mm
Dimensiuni
46 x 84 x 167mm
Best Temperature Measurement Accuracy
±1% + 1 °C
Best AC Voltage Accuracy
±1% + 3 Digits
Best Capacitance Measurement Accuracy
±1.9% + 2 Digits
Temperatura minima de lucru
-10°C
Inaltime
167mm
Greutate
550g
Best DC Current Accuracy
±1% + 2 Digits
Safety Category Voltage
600V
Battery Type
9V
Best Resistance Measurement Accuracy
±1.5% + 2 Digits
Lungime
46mm
Tara de origine
China
Detalii produs
Fluke 16 True RMS HVAC Digital Multimeter with Built-In Thermometer
The Fluke 16 Digital Multimeter is designed to function like a standard Multimeter and exclusive HVAC modes, unlike other models in the Fluke 10 series, the Fluke 116 comes with a built-in thermometer, allowing engineers to measure temperature and microamp mode for testing flame sensors to quickly troubleshoot problems for HVAC applications. The Fluke 116 measures resistance, continuity, frequency and capacitance. The Fluke 116 Multimeter are independently tested for safe use in CAT III 600 V Environments.
Standards
From Fluke, the 116 is designed for heating, ventilation and air conditioning (HVAC) engineers. The model includes temperature measurement and microamp current ranges to quickly troubleshoot HVAC problems.