Documente tehnice
Specificatii
Marca
AXINDUSSerie
HIFLEX-Y
Number of Cores
3
Cross Sectional Area
0.5 mm²
American Wire Gauge
20 AWG
Conductor Material
Bare Copper
Culoare invelis
Grey
Sheath Material
PVC
Control Cable Type
LIYY
Screen Type
Unscreened
Screened/Unscreened
Unscreened
Minimum Bend Radius
7 x Diameter
Diametru exterior
4.9mm
Lungime
50m
Tensiune
300 V
Curent nominal
8A
CPR Certification
Eca
Standarde
Euroclass Eca
Temperatura maxima de lucru
+70°C
Rezistenta la foc
Flame Retardant NF C 32-070/C2, IEC 60332-1
Earth Cable
No
Conductor Resistance
39 Ω/km
Insulation material
PVC
Filler Material
PVC
Frecventa minima de auto-rezonanta
-30°C
Oil Resistant
No
Cable Shape
Multi-Conductor
Tara de origine
Turkey
Detalii produs
Hi-FLEX-Y unscreened test cables (type LiYY)
Hi-FLEX®-Y cables are test and control cables suited for data transmission within electronics and automation or measurement systems. They are intended for use in internal fixed or partially mobile applications (without traction or forced guidance).
Standards
IEC 60332-1
Informatii indisponibile despre stoc
Incercati din nou mai tarziu
€ 1,66
Buc. (fara TVA)
€ 1,975
Buc. (cu TVA)
50
€ 1,66
Buc. (fara TVA)
€ 1,975
Buc. (cu TVA)
50
Documente tehnice
Specificatii
Marca
AXINDUSSerie
HIFLEX-Y
Number of Cores
3
Cross Sectional Area
0.5 mm²
American Wire Gauge
20 AWG
Conductor Material
Bare Copper
Culoare invelis
Grey
Sheath Material
PVC
Control Cable Type
LIYY
Screen Type
Unscreened
Screened/Unscreened
Unscreened
Minimum Bend Radius
7 x Diameter
Diametru exterior
4.9mm
Lungime
50m
Tensiune
300 V
Curent nominal
8A
CPR Certification
Eca
Standarde
Euroclass Eca
Temperatura maxima de lucru
+70°C
Rezistenta la foc
Flame Retardant NF C 32-070/C2, IEC 60332-1
Earth Cable
No
Conductor Resistance
39 Ω/km
Insulation material
PVC
Filler Material
PVC
Frecventa minima de auto-rezonanta
-30°C
Oil Resistant
No
Cable Shape
Multi-Conductor
Tara de origine
Turkey
Detalii produs
Hi-FLEX-Y unscreened test cables (type LiYY)
Hi-FLEX®-Y cables are test and control cables suited for data transmission within electronics and automation or measurement systems. They are intended for use in internal fixed or partially mobile applications (without traction or forced guidance).
Standards
IEC 60332-1