Documente tehnice
Specificatii
Marca
SchurterDimensiune siguranta
5 x 20 mm, 6.3 x 32 mm
Montare
PCB Mount
Clip Material
Brass
Latime
5.8mm
Lungime
12mm
Inaltime
11.5mm
Curent nominal
16A
Placa contact
Tin
Serie
751
Tensiune
600V ac/dc
Utilizare cu
5 x 20 mm Fuse, 6.3 x 32 mm Fuse
Tara de origine
Switzerland
Detalii produs
Schurter Fuseholder Mounting Accessories
Schurter Fuse Clips can be used in conjunction with schurter fuses to provide primary protection for electronic circuits. Fuse clips are available in a different mounting styles including solder and screw.
Panel Mounting
CATEGORIES OF PROTECTION AGAINST ELECTRIC SHOCK,PC1: No integral protection against electric shock. If required, designers must provide additional protection against electric shock on equipment.,PC2: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 standard test finger, when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.,PC3: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 1mm diameter rigid test wire when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.
P.O.A.
Buc. (Intr-un pachet de 50) (fara TVA)
50
P.O.A.
Buc. (Intr-un pachet de 50) (fara TVA)
50
Informatii despre stoc temporar indisponibile
Incercati din nou mai tarziu
Documente tehnice
Specificatii
Marca
SchurterDimensiune siguranta
5 x 20 mm, 6.3 x 32 mm
Montare
PCB Mount
Clip Material
Brass
Latime
5.8mm
Lungime
12mm
Inaltime
11.5mm
Curent nominal
16A
Placa contact
Tin
Serie
751
Tensiune
600V ac/dc
Utilizare cu
5 x 20 mm Fuse, 6.3 x 32 mm Fuse
Tara de origine
Switzerland
Detalii produs
Schurter Fuseholder Mounting Accessories
Schurter Fuse Clips can be used in conjunction with schurter fuses to provide primary protection for electronic circuits. Fuse clips are available in a different mounting styles including solder and screw.
Panel Mounting
CATEGORIES OF PROTECTION AGAINST ELECTRIC SHOCK,PC1: No integral protection against electric shock. If required, designers must provide additional protection against electric shock on equipment.,PC2: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 standard test finger, when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.,PC3: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 1mm diameter rigid test wire when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.