Schneider Electric C60 MCB Mini Circuit Breaker2P, 10A Curve C, 120 → 240V AC, 125V DC, 20 kA Breaking Capacity

Nr. stoc RS: 814-7463Producator: Schneider ElectricCod de producator: 60144
brand-logo
Vezi toate produsele din MCB

Documente tehnice

Specificatii

Numar poli

2

Curent nominal

10A

Tripping Characteristics

Type C

Rated AC Voltage

120 → 240V

Rated DC Voltage

125V

Breaking Capacity at Maximum Voltage Rating

20 kA

Dimensiune celula

C60

Lungime

107mm

Latime

36mm

Adancime

78.5mm

Tara de origine

France

Detalii produs

Schneider Electric Multi 9 C60N MCBs C Curve

C60N series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overload currents. Fully compliant with standards /EN 60947-2. Tripping curve type C that trips instantly at a rate of five to ten times its rated current. Multi 9 supplementary protectors and miniature circuit breakers limit let-through current, providing faster separation of the component from the fault, thereby reducing system damage. Reverse feeding of line power is permitted. Trip-free mechanism: Contacts cannot be held in the ON position when the C60 circuit breaker is tripped automatically.

Informatii indisponibile despre stoc

Incercati din nou mai tarziu

Informatii indisponibile despre stoc

P.O.A.

Schneider Electric C60 MCB Mini Circuit Breaker2P, 10A Curve C, 120 → 240V AC, 125V DC, 20 kA Breaking Capacity

P.O.A.

Schneider Electric C60 MCB Mini Circuit Breaker2P, 10A Curve C, 120 → 240V AC, 125V DC, 20 kA Breaking Capacity
Informatii indisponibile despre stoc

Documente tehnice

Specificatii

Numar poli

2

Curent nominal

10A

Tripping Characteristics

Type C

Rated AC Voltage

120 → 240V

Rated DC Voltage

125V

Breaking Capacity at Maximum Voltage Rating

20 kA

Dimensiune celula

C60

Lungime

107mm

Latime

36mm

Adancime

78.5mm

Tara de origine

France

Detalii produs

Schneider Electric Multi 9 C60N MCBs C Curve

C60N series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overload currents. Fully compliant with standards /EN 60947-2. Tripping curve type C that trips instantly at a rate of five to ten times its rated current. Multi 9 supplementary protectors and miniature circuit breakers limit let-through current, providing faster separation of the component from the fault, thereby reducing system damage. Reverse feeding of line power is permitted. Trip-free mechanism: Contacts cannot be held in the ON position when the C60 circuit breaker is tripped automatically.