Reliance 10bar Temperature and Pressure Relief Valve With Male BSP 1/2 in BSP Male Connection

Nr. stoc RS: 794-8457Producator: Reliance Water ControlsCod de producator: PTEM550755
brand-logo

Documente tehnice

Specificatii

Conexiune

1/2 in BSP Male

Maximum Set Pressure

10bar

Maximum Temperature

+95°C

Utilizare cu

Hot Water

Conexiune

Male

Dimensiune filet

1/4in

Filet standard

BSP

Tara de origine

United States

Detalii produs

Full Cartridge Pressure and Temperature Relief Valve

All Reliance pressure vessels are supplied with a replaceable membrane, which separates the water and air, to prevent contamination of the water system, corrosion of the pressure vessel or pressure loss in the water system.

Typically pressure vessels are used in pumped systems. When the pump starts, the pressure inside the vessel begins to increase. Once the vessel is full and the pump has reached its high pressure setting it will switch off. When water is then drawn off from the system the air pressure surrounding the membrane will force the water out of the pressure vessel and into the system. Once the membrane is fully deflated and the system has reached its minimum pressure, the pump will start on its low pressure setting and will begin the cycle again.

The purpose of this system is to prevent constant cycling of the pump and continuous running when the system is being used

Approvals

WRAS

Informatii indisponibile despre stoc

Incercati din nou mai tarziu

Informatii indisponibile despre stoc

P.O.A.

Reliance 10bar Temperature and Pressure Relief Valve With Male BSP 1/2 in BSP Male Connection

P.O.A.

Reliance 10bar Temperature and Pressure Relief Valve With Male BSP 1/2 in BSP Male Connection
Informatii indisponibile despre stoc

Documente tehnice

Specificatii

Conexiune

1/2 in BSP Male

Maximum Set Pressure

10bar

Maximum Temperature

+95°C

Utilizare cu

Hot Water

Conexiune

Male

Dimensiune filet

1/4in

Filet standard

BSP

Tara de origine

United States

Detalii produs

Full Cartridge Pressure and Temperature Relief Valve

All Reliance pressure vessels are supplied with a replaceable membrane, which separates the water and air, to prevent contamination of the water system, corrosion of the pressure vessel or pressure loss in the water system.

Typically pressure vessels are used in pumped systems. When the pump starts, the pressure inside the vessel begins to increase. Once the vessel is full and the pump has reached its high pressure setting it will switch off. When water is then drawn off from the system the air pressure surrounding the membrane will force the water out of the pressure vessel and into the system. Once the membrane is fully deflated and the system has reached its minimum pressure, the pump will start on its low pressure setting and will begin the cycle again.

The purpose of this system is to prevent constant cycling of the pump and continuous running when the system is being used

Approvals

WRAS