Parker PRT series 0.1s to 3s Pneumatic Timer, 8 bar max

Nr. stoc RS: 410-498Producator: ParkerCod de producator: PRT-E10
brand-logo

Documente tehnice

Specificatii

Marca

Parker

Maximum Time

3s

Minimum Time

0.1s

Temperatura maxima de lucru

+60°C

Producator

PRT

Presiune minima de operare

3bar

Presiune maxima de operare

8 bar

Temperatura minima de lucru

-15°C

Tara de origine

France

Detalii produs

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.

Informatii indisponibile despre stoc

Incercati din nou mai tarziu

Informatii indisponibile despre stoc

€ 238,24

Buc. (fara TVA)

€ 283,51

Buc. (cu TVA)

Parker PRT series 0.1s to 3s Pneumatic Timer, 8 bar max

€ 238,24

Buc. (fara TVA)

€ 283,51

Buc. (cu TVA)

Parker PRT series 0.1s to 3s Pneumatic Timer, 8 bar max
Informatii indisponibile despre stoc

Cumpara in pachete mari

CantitatePret unitar
1 - 4€ 238,24
5+€ 220,23

Documente tehnice

Specificatii

Marca

Parker

Maximum Time

3s

Minimum Time

0.1s

Temperatura maxima de lucru

+60°C

Producator

PRT

Presiune minima de operare

3bar

Presiune maxima de operare

8 bar

Temperatura minima de lucru

-15°C

Tara de origine

France

Detalii produs

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.