Eaton, MA3100 Surge Suppressor Unit 270 V ac Maximum Voltage Rating 45kA Maximum Surge Current 3 Phase

Nr. stoc RS: 621-8077Producator: EatonCod de producator: MA3145-230-4-R
brand-logo

Documente tehnice

Specificatii

Marca

Eaton

Tip supresor

3 Phase

Maximum Voltage Rating

270 V ac

Timp montare

DIN Rail

Curent supratensiune maxim

45kA

Dimensiune celula

MA3100

Lungime

89mm

Adancime

65mm

Inaltime

92mm

Dimensiuni

89 x 65 x 92mm

Frecventa minima de auto-rezonanta

-40°C

Temperatura maxima de lucru

+80°C

Detalii produs

Single & 3-phase Mains MA3100 Series

Surge protection designed to cope with high magnitude 10 / 350μs current waveforms as described in IEC 61312.

Approvals

UL 1449

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Informatii indisponibile despre stoc

Incercati din nou mai tarziu

Informatii indisponibile despre stoc

€ 459,35

Buc. (fara TVA)

€ 546,63

Buc. (cu TVA)

Eaton, MA3100 Surge Suppressor Unit 270 V ac Maximum Voltage Rating 45kA Maximum Surge Current 3 Phase

€ 459,35

Buc. (fara TVA)

€ 546,63

Buc. (cu TVA)

Eaton, MA3100 Surge Suppressor Unit 270 V ac Maximum Voltage Rating 45kA Maximum Surge Current 3 Phase
Informatii indisponibile despre stoc

Documente tehnice

Specificatii

Marca

Eaton

Tip supresor

3 Phase

Maximum Voltage Rating

270 V ac

Timp montare

DIN Rail

Curent supratensiune maxim

45kA

Dimensiune celula

MA3100

Lungime

89mm

Adancime

65mm

Inaltime

92mm

Dimensiuni

89 x 65 x 92mm

Frecventa minima de auto-rezonanta

-40°C

Temperatura maxima de lucru

+80°C

Detalii produs

Single & 3-phase Mains MA3100 Series

Surge protection designed to cope with high magnitude 10 / 350μs current waveforms as described in IEC 61312.

Approvals

UL 1449

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.