Eaton RCCB, 40A, 4 Pole, 300mA, Type B

Nr. stoc RS: 183-3548Producator: EatonCod de producator: 167897 FRCDM-40/4/03-G/B
brand-logo
Vezi toate produsele din RCCB

Documente tehnice

Specificatii

Marca

Eaton

Circuit Breaker Type

RCCB

Curent nominal

40A

Numar poli

4

Raza actiune

FRCdM

Sensibilitate scurgere

300mA

Tripping Characteristics

Type B

Dimensiune celula

Eaton Moeller

Adancime totala

80mm

Breaking Capacity at Maximum Voltage Rating

500 A

Dimensiuni totale

70 x 76 x 80mm

Tip contact terminal

Screw

Lungime totala

70mm

Break Time

Time Delay

Montare

DIN Rail Mount

Rated DC Voltage

220V

Rated AC Voltage

240V

Latime totala

76mm

Tara de origine

Czech Republic

Detalii produs

Eaton Residual Current Circuit Breakers (RCDs) - FRCdM Series Types B, B+ and Bfq

The FRCdM series of residual current devices from Eaton form part of the xEffect range providing the highest RCD protection for both people and appliances. These devices allow for permanent indication of actual electrical leakage with built in digital features.These types B, B+ and Bfq RCCBs detect AC pulsating, DC residual and smooth DC residual currents.

Type B RCCBs are the standard type and are sensitive to all residual current flows up to 1 kHZ. Type B+ devices are sensitive to all residual currents while also being equipped with a special tripping curve that limits the trip current to max. 420 mA for frequencies up to 20 kHz (Type B+ also meets superior fire protection regulations according to VDE 0664-400). Type Bfq devices meanwhile can tolerate system-induced earth leakage currents at higher frequencies up to 50 kHz.

Informatii indisponibile despre stoc

Incercati din nou mai tarziu

Informatii indisponibile despre stoc

€ 790,14

Buc. (fara TVA)

€ 940,27

Buc. (cu TVA)

Eaton RCCB, 40A, 4 Pole, 300mA, Type B

€ 790,14

Buc. (fara TVA)

€ 940,27

Buc. (cu TVA)

Eaton RCCB, 40A, 4 Pole, 300mA, Type B
Informatii indisponibile despre stoc

Documente tehnice

Specificatii

Marca

Eaton

Circuit Breaker Type

RCCB

Curent nominal

40A

Numar poli

4

Raza actiune

FRCdM

Sensibilitate scurgere

300mA

Tripping Characteristics

Type B

Dimensiune celula

Eaton Moeller

Adancime totala

80mm

Breaking Capacity at Maximum Voltage Rating

500 A

Dimensiuni totale

70 x 76 x 80mm

Tip contact terminal

Screw

Lungime totala

70mm

Break Time

Time Delay

Montare

DIN Rail Mount

Rated DC Voltage

220V

Rated AC Voltage

240V

Latime totala

76mm

Tara de origine

Czech Republic

Detalii produs

Eaton Residual Current Circuit Breakers (RCDs) - FRCdM Series Types B, B+ and Bfq

The FRCdM series of residual current devices from Eaton form part of the xEffect range providing the highest RCD protection for both people and appliances. These devices allow for permanent indication of actual electrical leakage with built in digital features.These types B, B+ and Bfq RCCBs detect AC pulsating, DC residual and smooth DC residual currents.

Type B RCCBs are the standard type and are sensitive to all residual current flows up to 1 kHZ. Type B+ devices are sensitive to all residual currents while also being equipped with a special tripping curve that limits the trip current to max. 420 mA for frequencies up to 20 kHz (Type B+ also meets superior fire protection regulations according to VDE 0664-400). Type Bfq devices meanwhile can tolerate system-induced earth leakage currents at higher frequencies up to 50 kHz.