Documente tehnice (Imaginile sunt cu titlu informativ. Va rugam sa consultati specificatiile tehnice.)
Specificatii
Marca
EA Elektro-AutomatikSerie
EL 9000
Load Type
Programmable
Constant Voltage Mode Range
0 → 750 V
Constant Current Mode Range
0 → 25 A
Constant Resistance Mode Range
0 → 40 Ω
Constant Wattage Mode Range
0 → 2400 W
Rack Units
2 U
Tara de origine
Germany
Detalii produs
EA-EL 9000 Series
The microprocessor controlled loads of the series EA-EL 9000 (2400W - 7200W) accomplish most requirements in modern load concepts for industrial and R&D areas. Four common regulation modes - constant voltage (CV), constant current (CC), constant power (CP) and constant resistance (CR) - can be used in combination with any of three operation modes (A, B and A/B). In static operation the two values A and B can be set using a fine adjustment encoder. The user can switch between these two values, or an external source can be used via the trigger input. In dynamic operation the microcontroller switches between A and B according to programmed time and interval. For each value a pulse interval between 50μs and 100s can be set. In addition, a ramp up and down of between 30μs and 200ms can be set.
Elektro-Automatik
P.O.A.
1
P.O.A.
Informatii despre stoc temporar indisponibile
1
Informatii despre stoc temporar indisponibile
Documente tehnice (Imaginile sunt cu titlu informativ. Va rugam sa consultati specificatiile tehnice.)
Specificatii
Marca
EA Elektro-AutomatikSerie
EL 9000
Load Type
Programmable
Constant Voltage Mode Range
0 → 750 V
Constant Current Mode Range
0 → 25 A
Constant Resistance Mode Range
0 → 40 Ω
Constant Wattage Mode Range
0 → 2400 W
Rack Units
2 U
Tara de origine
Germany
Detalii produs
EA-EL 9000 Series
The microprocessor controlled loads of the series EA-EL 9000 (2400W - 7200W) accomplish most requirements in modern load concepts for industrial and R&D areas. Four common regulation modes - constant voltage (CV), constant current (CC), constant power (CP) and constant resistance (CR) - can be used in combination with any of three operation modes (A, B and A/B). In static operation the two values A and B can be set using a fine adjustment encoder. The user can switch between these two values, or an external source can be used via the trigger input. In dynamic operation the microcontroller switches between A and B according to programmed time and interval. For each value a pulse interval between 50μs and 100s can be set. In addition, a ramp up and down of between 30μs and 200ms can be set.