Documente tehnice
Specificatii
Marca
Chauvin ArnouxRatio Range CT
0.8000 → 1000.0
Ratio Range (CT)
0.8000 → 1000.0
Ratio Range VT/PT
0.8000 → 8000.0 :1
Ratio Range (VT/PT)
0.8000 → 8000.0 :1
Excitation Voltage VT/PT
32Vrms
Excitation Voltage (VT/PT)
32Vrms
Excitation Signal CT
0 → 1 A, 0.1 → 4.5Vrms
Excitation Signal (CT)
0 → 1 A, 0.1 → 4.5Vrms
Test Frequencies
70Hz
Excitation Current Display
0 → 1A
Test Results Storage
10 000
Battery Life
10 h
Power Source
Battery
Temperatura maxima de lucru
+50°C
Frecventa minima de auto-rezonanta
-10°C
Protectie IP
IP40, IP53
Model
DTR 8510
Lungime
272mm
Tara de origine
United States
Detalii produs
DTR 8510 Digital Transformer Ratiometer
The DTR 8510 Dogital Transformer Ratiometer is fully automatic and uses the IEEE C57.12-90™-2006 test method. The DTR 8510 is a portable digital transformer ratiometer designed for on-site testing of power, potential and current transformers.When connected to a non-energized transformer, the DTR 8510 accurately measures the primary-to-secondary turns ratio, while simultaneouslydisplaying the polarity and excitation current.
Supplied with
DataViewⓇ analysis software
Standards
EN 61010-1, 50V CAT IV, Pollution Degree 2
Informatii indisponibile despre stoc
Incercati din nou mai tarziu
€ 5.898,19
Buc. (fara TVA)
€ 7.018,85
Buc. (cu TVA)
1
€ 5.898,19
Buc. (fara TVA)
€ 7.018,85
Buc. (cu TVA)
1
Documente tehnice
Specificatii
Marca
Chauvin ArnouxRatio Range CT
0.8000 → 1000.0
Ratio Range (CT)
0.8000 → 1000.0
Ratio Range VT/PT
0.8000 → 8000.0 :1
Ratio Range (VT/PT)
0.8000 → 8000.0 :1
Excitation Voltage VT/PT
32Vrms
Excitation Voltage (VT/PT)
32Vrms
Excitation Signal CT
0 → 1 A, 0.1 → 4.5Vrms
Excitation Signal (CT)
0 → 1 A, 0.1 → 4.5Vrms
Test Frequencies
70Hz
Excitation Current Display
0 → 1A
Test Results Storage
10 000
Battery Life
10 h
Power Source
Battery
Temperatura maxima de lucru
+50°C
Frecventa minima de auto-rezonanta
-10°C
Protectie IP
IP40, IP53
Model
DTR 8510
Lungime
272mm
Tara de origine
United States
Detalii produs
DTR 8510 Digital Transformer Ratiometer
The DTR 8510 Dogital Transformer Ratiometer is fully automatic and uses the IEEE C57.12-90™-2006 test method. The DTR 8510 is a portable digital transformer ratiometer designed for on-site testing of power, potential and current transformers.When connected to a non-energized transformer, the DTR 8510 accurately measures the primary-to-secondary turns ratio, while simultaneouslydisplaying the polarity and excitation current.
Supplied with
DataViewⓇ analysis software
Standards
EN 61010-1, 50V CAT IV, Pollution Degree 2