Documente tehnice
Specificatii
Marca
CastleMaximum Sound Level
140dB
Minimum Sound Level
35dB
Resolution
0.1 dB
DOSE Measurement
Yes
Greutate
A, C
Tip afisare
LCD
Battery Type
Alkaline, PP3
Fast/Slow Time Averaging
Both
Data Logging
Yes
Frecventa maxima
20kHz
Frecventa minima
1 Hz
Tara de origine
United Kingdom
Detalii produs
Castle GA216B Sonus Class 2 Sound Pressure Level Meter (non data logging version)
Castle GA216B is designed for general survey health & safety and engineering applications by industrial safety officers, occupational nurses, fire alarm installation & test engineers and industrial engineers. It gives clear results which meet the requirements of international standards. GA216B is a Sonus range entry-level Type 2 sound meter fully compliant with IEC 61672-1:2002. The difference between Type 1 and Type 2 is in the tolerance, for example: at reference frequency 1kHz, tolerance is ±1.1dB (Type 1) and ±1.4dB (Type 2); at 20Hz, tolerance is ±2.5dB (Class 1) and ±3.5dB (Class 2). Compliance with IEC 61672-1:2002 Class 2 and IEC 60651:1979 Type 2 is necessary for carrying out most noise assessment tasks in industry.
Standards
IEC 61672-1:2002 Class 2, IEC 60651: 1979 Type 2
Informatii indisponibile despre stoc
Incercati din nou mai tarziu
€ 821,99
Buc. (fara TVA)
€ 978,17
Buc. (cu TVA)
1
€ 821,99
Buc. (fara TVA)
€ 978,17
Buc. (cu TVA)
1
Documente tehnice
Specificatii
Marca
CastleMaximum Sound Level
140dB
Minimum Sound Level
35dB
Resolution
0.1 dB
DOSE Measurement
Yes
Greutate
A, C
Tip afisare
LCD
Battery Type
Alkaline, PP3
Fast/Slow Time Averaging
Both
Data Logging
Yes
Frecventa maxima
20kHz
Frecventa minima
1 Hz
Tara de origine
United Kingdom
Detalii produs
Castle GA216B Sonus Class 2 Sound Pressure Level Meter (non data logging version)
Castle GA216B is designed for general survey health & safety and engineering applications by industrial safety officers, occupational nurses, fire alarm installation & test engineers and industrial engineers. It gives clear results which meet the requirements of international standards. GA216B is a Sonus range entry-level Type 2 sound meter fully compliant with IEC 61672-1:2002. The difference between Type 1 and Type 2 is in the tolerance, for example: at reference frequency 1kHz, tolerance is ±1.1dB (Type 1) and ±1.4dB (Type 2); at 20Hz, tolerance is ±2.5dB (Class 1) and ±3.5dB (Class 2). Compliance with IEC 61672-1:2002 Class 2 and IEC 60651:1979 Type 2 is necessary for carrying out most noise assessment tasks in industry.
Standards
IEC 61672-1:2002 Class 2, IEC 60651: 1979 Type 2