Documente tehnice
Specificatii
Marca
Analog DevicesSensor Function
Temperature
Tip iesire
Analogue
Interfata
Analogue
Acuratete
±4°C
Timp montare
Through Hole
Numar pini
10
Temperatura de lucru
-55 to +125 °C
Temperatura minima de lucru
-55 °C
Temperatura maxima de lucru
+125 °C
Minimum Operating Supply Voltage
5 V
Maximum Operating Supply Voltage
30 V
Tip pachet
TO-100
Lungime
9.4mm
Inaltime
4.7mm
Latime
9.4mm
Sensor Gain
10mV/°C
Dimensiuni
9.4 x 9.4 x 4.7mm
Detalii produs
AD595...AD597 Thermocouple Amplifiers, Analog Devices
The AD594/595/596/597 series of type J/K thermocouple amplifiers are a combination of an instrumentation amplifier and thermocouple cold junction compensator roviding an output of 10mV/°C.
AD594 for type J thermocouples, optimised operating temperature range 0°C to 50°C
AD595 for type K thermocouples, optimised operating temperature range 0°C to 50°C
AD596 for type J thermocouples, optimised operating temperature range 25°C to 100°C
AD597 for type K thermocouples, optimised operating temperature range 25°C to 100°C
All versions have a measurement range equal to the full range of the relevant thermocouple type.
Thermocouple Amplifiers
Informatii indisponibile despre stoc
Incercati din nou mai tarziu
P.O.A.
1
P.O.A.
1
Documente tehnice
Specificatii
Marca
Analog DevicesSensor Function
Temperature
Tip iesire
Analogue
Interfata
Analogue
Acuratete
±4°C
Timp montare
Through Hole
Numar pini
10
Temperatura de lucru
-55 to +125 °C
Temperatura minima de lucru
-55 °C
Temperatura maxima de lucru
+125 °C
Minimum Operating Supply Voltage
5 V
Maximum Operating Supply Voltage
30 V
Tip pachet
TO-100
Lungime
9.4mm
Inaltime
4.7mm
Latime
9.4mm
Sensor Gain
10mV/°C
Dimensiuni
9.4 x 9.4 x 4.7mm
Detalii produs
AD595...AD597 Thermocouple Amplifiers, Analog Devices
The AD594/595/596/597 series of type J/K thermocouple amplifiers are a combination of an instrumentation amplifier and thermocouple cold junction compensator roviding an output of 10mV/°C.
AD594 for type J thermocouples, optimised operating temperature range 0°C to 50°C
AD595 for type K thermocouples, optimised operating temperature range 0°C to 50°C
AD596 for type J thermocouples, optimised operating temperature range 25°C to 100°C
AD597 for type K thermocouples, optimised operating temperature range 25°C to 100°C
All versions have a measurement range equal to the full range of the relevant thermocouple type.