Documente tehnice
Specificatii
Marca
Phoenix ContactTensiune
250V ac
Curent supratensiune maxim
120kA
Montare
DIN Rail
Impulse Discharge Current
60kA
Lungime
98.5mm
Latime
49.2mm
Adancime
70mm
Dimensiuni
98.5 x 49.2 x 70mm
Temperatura minima de lucru
-40°C
Temperatura maxima de lucru
+80°C
Temperatura de lucru
-40 → +80 °C
Tara de origine
Germany
Detalii produs
Single & 3-phase Mains FLT & VAL Series
Pluggable modules on a fixed base element, for easy installation and fast replacement.
Standards
IEC 61643, VDE V 0185-3
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
Informatii indisponibile despre stoc
Incercati din nou mai tarziu
P.O.A.
1
P.O.A.
1
Documente tehnice
Specificatii
Marca
Phoenix ContactTensiune
250V ac
Curent supratensiune maxim
120kA
Montare
DIN Rail
Impulse Discharge Current
60kA
Lungime
98.5mm
Latime
49.2mm
Adancime
70mm
Dimensiuni
98.5 x 49.2 x 70mm
Temperatura minima de lucru
-40°C
Temperatura maxima de lucru
+80°C
Temperatura de lucru
-40 → +80 °C
Tara de origine
Germany
Detalii produs
Single & 3-phase Mains FLT & VAL Series
Pluggable modules on a fixed base element, for easy installation and fast replacement.
Standards
IEC 61643, VDE V 0185-3
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.