Documente tehnice
Specificatii
Marca
DehnTip supresor
Surge Arrester
Maximum Voltage Rating
255 V ac
Timp montare
Flush Mount
Curent supratensiune maxim
3kA
Serie
DFL
Lungime
30mm
Adancime
11mm
Inaltime
50mm
Dimensiuni
30 x 11 x 50mm
Temperatura minima de lucru
-25°C
Temperatura maxima de lucru
+40°C
Tara de origine
Germany
Detalii produs
DEHNflex with Acoustic Fault Indication
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
€ 158,44
€ 158,44 Buc. (fara TVA)
€ 188,54
€ 188,54 Buc. (cu TVA)
1
€ 158,44
€ 158,44 Buc. (fara TVA)
€ 188,54
€ 188,54 Buc. (cu TVA)
1
Informatii despre stoc temporar indisponibile
Incercati din nou mai tarziu
Cantitate | Pret unitar |
---|---|
1 - 4 | € 158,44 |
5 - 9 | € 150,66 |
10 - 19 | € 141,43 |
20 - 29 | € 127,75 |
30+ | € 112,79 |
Documente tehnice
Specificatii
Marca
DehnTip supresor
Surge Arrester
Maximum Voltage Rating
255 V ac
Timp montare
Flush Mount
Curent supratensiune maxim
3kA
Serie
DFL
Lungime
30mm
Adancime
11mm
Inaltime
50mm
Dimensiuni
30 x 11 x 50mm
Temperatura minima de lucru
-25°C
Temperatura maxima de lucru
+40°C
Tara de origine
Germany
Detalii produs
DEHNflex with Acoustic Fault Indication
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.