Testere multifunctionale
Multifunction testers or MFTs are handheld versatile devices used to verify the safety of electrical installations in domestic, commercial, and industrial settings. These installation testers are designed to streamline and simplify electrical testing processes and ensure that fixed wiring is safe and correctly installed to meet relevant local standards and safety requirements
Multifunctio...
Se afiseaza 1-20 din 112 produse

Nr. stoc RS: 200-3705Producator: RS PRO
€ 64,38
€ 64,38 Buc. (fara TVA)
Verifica stocul
1

Nr. stoc RS: 200-3704Producator: RS PRO
€ 26,60
€ 26,60 Buc. (fara TVA)
Verifica stocul
1
RS Pro
-
-
No
-
-
-
-
48V
Auto Test
-
-
-
-
-
-
-
-
86 x 37 x 28.5mm
68g
LCD - Backlit
Battery
-
28.5mm
37mm
-
-
12 V
86mm
-
-
-
-
-
-
-

Nr. stoc RS: 177-9342Producator: RS PRO
€ 1.297,22
€ 1.297,22 1 Kit (fara TVA)
Verifica stocul
1
RS Pro
-
Phase to Earth
Yes
Yes
MT-6600
Yes
1000V
1000V
-
-
-
Bluetooth
1mA
-
-
IP67
-
242 x 105 x 145mm
1.6kg
LCD
Battery
600V
105mm
145mm
0°C
+45°C
-
242mm
CAT III
-
CAT III 600V
-
-
0Ω
2000Ω
Fluke
-
3 Wire
-
-
1651B
Yes
250 V, 500 V, 1000 V
500V ac
Continuity, Wiring Polarity
-
-
UK Mains
200mA
AC Type
BS 7671, EN 61010-I, HD 384, IEC 60364
IP40
-
100 x 250 x 125mm
1.5kg
LCD
Battery, Mains
300 V, 500 V
250mm
125mm
-10°C
+40°C
AA
100mm
CAT III, CAT IV
Type F - Schuko plug, Type G - British 3-pin
CAT III 500 V, CAT IV 300 V
-
-
20Ω
2000Ω
Fluke
-
3 Wire
Yes
Yes
1653B
Yes
50 V, 100 V, 250 V, 500 V, 1000 V
500V ac
Continuity, Wiring Polarity
Yes
Yes
-
200mA
AC Type
EN 61010-I, HD 384, IEC 60364
IP40
-
100 x 250 x 125mm
1.3kg
LCD
Battery, Mains
300 V, 500 V
250mm
125mm
-10°C
+40°C
AA
100mm
CAT III, CAT IV
Type G - British 3-pin
CAT III 500 V, CAT IV 300 V
-
-
20Ω
2000Ω
Fluke
-
-
-
-
T6-600
-
-
600V ac
AC Current, AC Voltage, DC Voltage, Resistance
-
-
-
-
-
-
-
-
61.1 x 43.8 x 259.3mm
350g
Digital
-
600V
43.8mm
259.3mm
-10°C
+50°C
AA IEC LR6
61.1mm
CAT III
-
-
-
-
-
-
Fluke
-
-
Yes
No
T5
-
-
600V ac
AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Resistance
-
-
-
-
-
-
-
-10 → +50 °C
30.5 x 51 x 203mm
300g
-
Battery
600V
51mm
203mm
-10°C
+50°C
AA x 2
30.5mm
CAT III
-
CAT III 600 VV
0 to 600V
0 → 1000 O
0Ω
-
Fluke
-
Phase to Earth, Phase to Neutral
Yes
Yes
1662
No
100 V, 250 V, 500 V, 1000 V
500V ac/dc
Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity
-
Yes
-
10mA
A, AC
IEC 60364
IP40
-
100 x 250 x 125mm
1.3 (with Battery)kg
-
Battery
300 V, 500 V
250mm
125mm
-
-
AA
100mm
CAT III, CAT IV
UK
CAT III 500 V, CAT IV 300 V
100 → 1000V
-
20Ω
2000Ω
Kewtech Corporation
-
2 Wire, 3 Wire
Yes
Yes
KT65DL
Yes
100V
500V
Continuity
Yes
Yes
USB
200mA
AC Type
EN 61557, IEC 61557
IP40
-
235 x 136 x 114mm
1.4kg
Backlight
Battery
300V
136mm
114mm
0°C
+40°C
AA, LR6
235mm
CAT III
-
CAT III 300 V
-
-
20Ω
2000Ω
Martindale
-
-
-
-
ET4
-
-
600V ac
-
-
-
-
-
-
-
-
-
202.5 x 51 x 44mm
200g
LCD
Battery
600V
51mm
44mm
0°C
+40°C
9V
202.5mm
CAT III
-
CAT III 600V
-
-
-
-
Fluke
-
-
Yes
No
T5
-
-
1000V ac
AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Resistance
-
-
-
-
-
-
-
-10 → +50 °C
30.5 x 51 x 203mm
300g
-
Battery
600 V, 1000 V
51mm
203mm
-10°C
+50°C
AA x 2
30.5mm
CAT III, CAT IV
-
CAT IV 600 V / CAT III 1000 VV
0 to 1000V
25 → 400 O
0Ω
1000Ω