Testere multifunctionale
Multifunction testers or MFTs are handheld versatile devices used to verify the safety of electrical installations in domestic, commercial, and industrial settings. These installation testers are designed to streamline and simplify electrical testing processes and ensure that fixed wiring is safe and correctly installed to meet relevant local standards and safety requirements
Multifunctio...
Se afiseaza 1-20 din 112 produse

Nr. stoc RS: 200-3705Producator: RS PRO
€ 64,38
€ 64,38 Buc. (fara TVA)
Verifica stocul
1

Nr. stoc RS: 200-3704Producator: RS PRO
€ 26,60
€ 26,60 Buc. (fara TVA)
Verifica stocul
1
RS Pro
-
-
No
-
-
-
-
48V
Auto Test
-
-
-
-
-
-
-
12 V
-
37mm
-
86 x 37 x 28.5mm
-
-
28.5mm
-
Battery
-
-
-
86mm
-
68g
LCD - Backlit
-
-

Nr. stoc RS: 177-9342Producator: RS PRO
€ 1.297,22
€ 1.297,22 1 Kit (fara TVA)
Verifica stocul
1
RS Pro
-
Phase to Earth
Yes
Yes
MT-6600
Yes
1000V
1000V
-
-
-
Bluetooth
1mA
-
IP67
-
-
600V
145mm
-
242 x 105 x 145mm
0Ω
2000Ω
105mm
-
Battery
CAT III 600V
0°C
-
242mm
-
1.6kg
LCD
CAT III
+45°C
Fluke
-
3 Wire
-
-
1651B
Yes
250 V, 500 V, 1000 V
500V ac
Continuity, Wiring Polarity
-
-
UK Mains
200mA
AC Type
IP40
BS 7671, EN 61010-I, HD 384, IEC 60364
AA
300 V, 500 V
125mm
-
100 x 250 x 125mm
20Ω
2000Ω
250mm
Type F - Schuko plug, Type G - British 3-pin
Battery, Mains
CAT III 500 V, CAT IV 300 V
-10°C
-
100mm
-
1.5kg
LCD
CAT III, CAT IV
+40°C
Fluke
-
3 Wire
Yes
Yes
1653B
Yes
50 V, 100 V, 250 V, 500 V, 1000 V
500V ac
Continuity, Wiring Polarity
Yes
Yes
-
200mA
AC Type
IP40
EN 61010-I, HD 384, IEC 60364
AA
300 V, 500 V
125mm
-
100 x 250 x 125mm
20Ω
2000Ω
250mm
Type G - British 3-pin
Battery, Mains
CAT III 500 V, CAT IV 300 V
-10°C
-
100mm
-
1.3kg
LCD
CAT III, CAT IV
+40°C
Fluke
-
-
-
-
T6-600
-
-
600V ac
AC Current, AC Voltage, DC Voltage, Resistance
-
-
-
-
-
-
-
AA IEC LR6
600V
259.3mm
-
61.1 x 43.8 x 259.3mm
-
-
43.8mm
-
-
-
-10°C
-
61.1mm
-
350g
Digital
CAT III
+50°C
Fluke
-
-
Yes
No
T5
-
-
600V ac
AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Resistance
-
-
-
-
-
-
-
AA x 2
600V
203mm
-10 → +50 °C
30.5 x 51 x 203mm
0Ω
-
51mm
-
Battery
CAT III 600 VV
-10°C
0 → 1000 O
30.5mm
0 to 600V
300g
-
CAT III
+50°C
Fluke
-
Phase to Earth, Phase to Neutral
Yes
Yes
1662
No
100 V, 250 V, 500 V, 1000 V
500V ac/dc
Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity
-
Yes
-
10mA
A, AC
IP40
IEC 60364
AA
300 V, 500 V
125mm
-
100 x 250 x 125mm
20Ω
2000Ω
250mm
UK
Battery
CAT III 500 V, CAT IV 300 V
-
-
100mm
100 → 1000V
1.3 (with Battery)kg
-
CAT III, CAT IV
-
Kewtech Corporation
-
2 Wire, 3 Wire
Yes
Yes
KT65DL
Yes
100V
500V
Continuity
Yes
Yes
USB
200mA
AC Type
IP40
EN 61557, IEC 61557
AA, LR6
300V
114mm
-
235 x 136 x 114mm
20Ω
2000Ω
136mm
-
Battery
CAT III 300 V
0°C
-
235mm
-
1.4kg
Backlight
CAT III
+40°C
Martindale
-
-
-
-
ET4
-
-
600V ac
-
-
-
-
-
-
-
-
9V
600V
44mm
-
202.5 x 51 x 44mm
-
-
51mm
-
Battery
CAT III 600V
0°C
-
202.5mm
-
200g
LCD
CAT III
+40°C
Fluke
-
-
Yes
No
T5
-
-
1000V ac
AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Resistance
-
-
-
-
-
-
-
AA x 2
600 V, 1000 V
203mm
-10 → +50 °C
30.5 x 51 x 203mm
0Ω
1000Ω
51mm
-
Battery
CAT IV 600 V / CAT III 1000 VV
-10°C
25 → 400 O
30.5mm
0 to 1000V
300g
-
CAT III, CAT IV
+50°C